Coefficient de corrélation et champ magnétique pour la détection de court-circuit entre spires dans les machines synchrones
Résumé
This paper presents a non-invasive method for detecting the presence of an inter-turn short circuit in the stator windings of a synchronous machine. This method relies on the use of the Pearson Correlation Coefficient for analyzing the external magnetic field measured by multiple sensors placed around the machine's frame. The results show a high correlation (around 0.99) in the absence of faults, but a significant decrease for faults involving 3 or 5 windings, enabling fault diagnosis. This method appears promising for synchronous machine monitoring as it is sensitive to minor faults. Additionally, we observe that the correlation depends on the sensors' placement relative to the fault location.
Cet article présente une méthode non invasive pour détecter et évaluer la gravité des défauts de court-circuit entre les spires statoriques d'une machine synchrone. Cette méthode repose sur l'utilisation du coefficient de corrélation de Pearson pour l'analyse du champ magnétique externe mesuré par plusieurs capteurs placés autour de la carcasse de la machine. Les résultats montrent une corrélation élevée (de l'ordre de 0.99) en l'absence de défaut, et une diminution significative de celle-ci pour les défauts impliquant 3 ou 5 spires, ce qui permet le diagnostic du défaut. Cette méthode semble intéressante pour la surveillance des machines synchrones, car elle est sensible aux défauts mineurs. De plus, nous observons que la corrélation dépend de l'emplacement des capteurs par rapport à la localisation du défaut.